Battery charger fault codes, Battery charger fault codes -3 – JLG 1230ES Operator Manual User Manual
Page 45

SECTION 4 - MACHINE OPERATION
3121221
– JLG Lift –
4-3
Battery Charger Fault Codes
If a fault occurred during charging, the red "Fault" LED
(located on the Ground Control Station panel) will flash with
a code corresponding to the error. Refer to the table fol-
lowing for the flash codes and their removal.
If required, further general and troubleshooting information
about the battery charger can be found in the charger manufac-
turers Owner’s Guide included in the manual storage box
mounted on the machine.
Table 4-1. Battery Charger Fault Codes
FLASH(s)
FAULT
MODE(S) AFFECTED
REMEDY
1
High battery voltage
Invert or Charge
Discharge battery, unit will auto start.
2
Low battery voltage
Invert or Charge
Connect qualified external AC to charge batteries.
3
Charge time is greater than 20 hrs.
Charge
Remove DC loads or replace batteries.
4
Shorted battery
Charge
Replace Battery.
5
Over-temperature
Invert
Turn the toggle switch to Standby and allow inverter/charger to cool.
6
Over load
Over current
Invert or Charge
Remove excessive AC loads and reset unit by turning the toggle switch to Standby
they ON.