1 power-up, 2 platform controls, 1 power-up -14 2-2 platform controls -14 – JLG 1230ES Operator Manual User Manual
Page 78: 0 help comments

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-14
– JLG Lift –
3121221
009
DRIVE PREVENTED - ELEVATED ABOVE
DRIVE CUTOUT HEIGHT
The platform is elevated above the cali-
brated cutout height.
• Check that the elevation angle sensor is securely mounted.
Refer problem to a qualified JLG mechanic.
0-0 Help Comments
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
2-1 Power-Up
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
211
POWER CYCLE
This help message is issued at each power
cycle. Displays on the analyzer only.
Normal operation. No check necessary.
212
KEYSWITCH FAULTY
Both platform and ground modes are
selected simultaneously. Defaults to
ground mode.
Refer problem to a qualified JLG mechanic.
2-2 Platform Controls
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
221
FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED
The horn switch was closed during power-
up in platform mode.
• Check if the horn switch is damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.
222
FUNCTION PROBLEM - INDOOR / OUT-
DOOR PERMANENTLY SELECTED
The indoor / outdoor (zone A / zone B)
switch was closed during power-up in plat-
form mode.
• Check if the indoor/outdoor (zone A / zone B) capacity switch is damaged,
obstructed or jammed.
Refer problem to a qualified JLG mechanic.