Battery charger fault codes, Battery charger fault codes -28, 11 battery charger fault codes -28 – JLG X390AJ Operator Manual User Manual
Page 130

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-28
– JLG Lift –
3128792
Battery Charger Fault Codes
(See “Errors Menu” on page 6-20 info for display information)
Table 6-11. Battery Charger Fault Codes
CODE
DESCRIPTION
STATUS
ACTION
8
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
13
Communication pro.blem with external mem-
ory.
Battery charger stops working.
Contact service dept. or change product.
18
Extended shutdown or power failure.
Battery charger stops supplying power. Opera-
tion resumes as soon as alarm conditions are
no longer present or after restarting.
If problem is a power failure, check battery
charger mains power supply.
19
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
240
Digital input is open and managed as hardware
start-stop.
Battery charger stops charging until digital
input closes.
Close digital input.
241
Problem in CANBUS communication with other
systems in the network.
The way this is managed may change based on
different firmware releases.
Check correct operation of CANBUS system.
242
Error when reading internal memory on micro-
controller.
Battery charger stops working.
Contact service dept. or change product.
244
Mains voltage lower than maximum operating
range tolerance.
Battery charger won’t start charging until mains
voltage returns within normal operating range.
Make sure mains voltage is within correct oper-
ating parameters.
245
Abnormal current draw in primary section.
Battery charger stops supplying power. Opera-
tion resumes as soon as alarm conditions are
no longer present.
If problem persists, contact service dept. or
change product.