Bms fault codes - (battery management system), Bms fault codes - (battery management system) -26 – JLG X390AJ Operator Manual User Manual
Page 128

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-26
– JLG Lift –
3128792
BMS Fault Codes - (Battery Management
System)
(See “Errors Menu” on page 6-20 info for display information)
NOTE: The CODE column indicates the CAN CODE in the
message sent by the battery charger. The normal
mains voltage tolerance is the rated value ±15%.
CODE – TYPE OF ERROR
A99E01 – Configuration error
A99E02 – Incorrect voltage
A99E03 – Incorrect temperature
A99E04 – Excess discharge current
A99E05 – Excess charge current
A99E06 – Pre.charge error
A99E07 – No 12 V power supply
A99E08 – No 12 V power supply
A99E09 – High battery compartment temperature
A99E10 – High electronic board temperature
A99E11 – Incorrect self.protection device temperature
A99E12 – Fault on all temperature sensors
A99E13 – Temperature sensor fault
A99E14 – Earth connection fault
79
Incorrect start
Cause – Incorrect starting procedure.
Solution – Check electrical connections. This is generally a tem-
porary problem due to certain working conditions. If problem per-
sists, replace inverter.
86
Pedal wire KO
Cause –
Solution – This is generally a temporary problem due to certain
working conditions. If problem persists, replace inverter.
93
Wrong set batt
Cause – With power connected, battery test detected incorrect
batteries fitted.
Solution – Replace batteries with the original ones supplied
directly by JLG.
94
Current sensor KO
Cause – Set up procedure for maximum current in progress.
Solution – Contact JLG after-sales service.
99
Check up needed
Cause –
Solution – Contact Hinowa after.sales service.
Table 6-10. Inverter Fault Codes
CODE
DESCRIPTION