SECTION 6 - JLG CONTROL SYSTEM
3121607
– JLG Lift –
6-33
DISPLAY UNITS:
22*
0
1
IMPERIAL: DEG F, PSI, LBS
METRIC: DEG C, KPA, KGS.
0
* Certain market selections will alter default setting.
DRIVE CONTROL:
24
0
1
2
NORMAL: Drive coils are energized from the Ground Module.
PROPULSION: Drive coils are energized from the Propulsion Module.
ENHANCED: Drive coils are energized from the Ground Module and the
ground side of the drive coils are brought back to current feedback returns.
2
BOOM CONTROL:
26
0
1
NORMAL: Boom control coils are energized from the Ground Module.
ENHANCED: Boom control coils are energized from the Ground Module and
the ground side of the drive coils are brought back to current feedback
returns.
0
FUNCTION SPEED
KNOB:
27
0
1
YES: Machine is equipped with Function Speed Knob.
NO: Machine is equipped with Operation Speed Knob.
0
CLEARSKY:
28
0
1
NO: ClearSky (Telematics )system option is disabled.
YES: ClearSky (Telematics) system is enabled
0
CRIBBING OPTION:
29
0
1
NO: Cribbing Option is disabled.
YES: Cribbing Option is enabled.
0
FUEL TANK SIZE:
30
0
1
31 Gallon tank.
52 Gallon tank.
0
ALARM/HORN:
31
0
1
SEPERATE: Separate alarm and horn.
COMBINED: combination alarm/horn.
0
ALERT BEACON
32
0
1
OFF FOR CREEP: Alert beacon will not flash in Creep.
20 FPS FOR CREEP: Alert beacon will flash at 20 FPS while in Creep.
0
4150364 G
Table 6-5. Machine Configuration Programming Information
Configuration Digit
Number
Description
Default
Number