JLG 600SC_660SJC Service Manual User Manual
Page 222

SECTION 6 - JLG CONTROL SYSTEM
6-28
– JLG Lift –
3121607
JIB DOWN SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB LEFT SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB LEFT OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB LEFT SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB RIGHT SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB RIGHT OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
JIB RIGHT SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER UP SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER UP OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER UP SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER DOWN SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER DOWN OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER DOWN SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER IN SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER IN OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER IN SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER OUT SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER OUT OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
TOWER OUT SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER IN SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER IN OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER IN SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER OUT SHORT TO GROUND
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER OUT OPEN CIRCUIT
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
UPPER OUT SHORT TO BATTERY
3
3
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
FUEL SENSOR SHORT TO BATTERY
3
3
CLEARS WHEN FAULT IS REMOVED
FUEL SENSOR SHORT TO GROUND
3
3
CLEARS WHEN FAULT IS REMOVED
OIL PRESSURE SHORT TO BATTERY
4
3
CLEARS WHEN FAULT IS REMOVED
OIL PRESSURE SHORT TO GROUND
4
3
CLEARS WHEN FAULT IS REMOVED
COOLANT TEMPERATURE SHORT TO GROUND
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 12
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 13
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 14
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 15
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 21
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 22
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 23
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 24
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 25
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 26
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 31
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 32
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 33
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 34
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 35
4
3
CLEARS WHEN FAULT IS REMOVED
FORD FAULT CODE 36
4
3
CLEARS WHEN FAULT IS REMOVED
Table 6-4. Help Message/Fault Listing
HELP MESSAGE
FAULT
FAULT REMOVAL