Normal engine operation, Stopping the engine – JLG G6-42A Operator Manual User Manual
Page 25

Form No. 20036 • G6-42A Owner/Operator Manual
Normal Engine Operation
Observe gauges frequently to be sure all engine systems are functioning
properly.
The voltmeter shows the “charge/discharge” state of the battery charging system.
With the engine running, meter should indicate 13.5 to 14 volts. With engine
stopped, meter indicates battery charge (12 volts).
Be alert for unusual noises or vibration. When an unusual condition is noticed,
park machine in safe position and perform standard shut-down procedure. (See
Page 1.1) Report condition to your supervisor or maintenance personnel.
Avoid prolonged idling. Idling causes engine temperature to drop and this
permits formation of heavy carbon deposits and dilution of lubricating oil by
incompletely-burned fuel. If the engine is not being used, turn it off.
Stopping the Engine
• To stop engine, perform standard shut-down procedure.
• Operate engine at low idle for 3 to 5 minutes before turning it off. This
allows engine coolant and lubricating oil to carry excessive heat away from
critical engine areas, including turbocharger.
• Do not “gun” engine before shut down: This practice causes incompletely-
burned fuel to remove oil film from cylinder walls and dilute lubricant in
crankcase.
6.1