Assigning a vlan to a spanning tree group – Blade ICE G8000 User Manual
Page 77

RackSwitch G8000 Application Guide
Chapter 5: Spanning Tree
77
BMD00041, November 2008
Assigning a VLAN to a Spanning Tree Group
If no VLANs exist beyond the default VLAN 1 see
for
information on adding ports to VLANs.
Assign the VLAN to the STG using the following command:
If the association between the spanning-tree group and a VLAN is broken, the spanning-
tree parameters are cleared. Reconfigure all of the parameters for the STG.
Each STG must have a VLAN assigned to it before it becomes functional. You cannot
configure other STG settings until the VLAN is assigned. If the STG VLAN is unas-
signed, other configuration settings are cleared. Assign a VLAN and reconfigure the STG
settings.
N
OTE
– To ensure proper operation with switches that use Cisco Per VLAN Spanning
Tree (PVST+), you must either:
create a separate STG for each VLAN, or
manually add all associated VLANs into a single STG.
RS G8000 (config-if)# spanning-tree stp 1 vlan
<1-4094>