beautypg.com

Listing current users, Logging into an end user account – Blade ICE G8000 User Manual

Page 37

background image

RackSwitch G8000 Application Guide

Chapter 1: Accessing the Switch

„

37

BMD00041, November 2008

Defining a User’s access level

The end user is by default assigned to the user access level (also known as class of service, or
COS). COS for all user accounts have global access to all resources except for User COS,
which has access to view only resources that the user owns. For more information, see

Table

1-1 “User Access Levels” on page 29

.

To change the user’s level, select one of the following options:

Enabling or Disabling a User

An end user account must be enabled before the switch recognizes and permits login under the
account. Once enabled, the switch requires any user to enter both username and password.

Listing current Users

The following command displays defined user accounts and whether or not each user is cur-
rently logged into the switch.

Logging into an End User account

Once an end user account is configured and enabled, the user can login to the switch using the
username/password combination. The level of switch access is determined by the COS estab-
lished for the end user account.

RS G8000 (config)# access user 1 level {user|operator|administrator}

RS G8000 (config)# access user 1 enable

RS G8000 (config)# no access user 1 enable

RS G8000# show access user

Usernames:

user - Enabled - offline

oper - Disabled - offline

admin - Always Enabled - online 1 session

Current User ID table:

1: name jane , ena, cos user , password valid, online 1 session

2: name john , ena, cos user , password valid, online 2 sessions