beautypg.com

Caution – Snorkel TB66J CE User Manual

Page 44

background image

Chapter 8 – Operation

40

TB60/66J – 0084030EE

A

Caution

Not all hydraulic fluid is suitable to use in the hy-

draulic system. Some have poor lubricating char-

acteristics and can increase component wear. Only

use hydraulic fluid as recommended.

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of

-2°C (0°F) or below.

Preparing for Operation

Use the following procedure to prepare the aerial plat-

form for operation.

. Perform a prestart inspection as described in Chap-

ter 7.

2. Place the battery disconnect switch in the on posi-

tion.

3. Close and latch the doors.

4. Before painting or sandblasting make sure the

sandblast protection kit and the platform control

cover are properly installed. These options, when

used properly will protect the control placards and

cylinder rods from paint overspray and abrasion

while sandblasting.

Lower Controls

The lower controls override the upper controls. This

means that the lower controls can always be used to

operate the platform regardless of the position of the

upper control emergency stop button.

Boom, turntable, and platform functions may be oper-

ated from the lower controls. The lower controls may

be used for initial set up of the aerial platform, and for

testing and inspection.

Use the following procedure to operate boom, turntable,

or platform functions using the lower controls. Refer to

Figure 8.2.

. Pull the emergency stop button (refer to Figure 8.2)

outward. Insert the key in the control selector and

turn the switch to the lower control position.

2. Press the start button until the engine starts, then

release. The engine will not start if the control selec-

tor switch is left in the lower control position for 30

seconds or longer before starting the engine. The

control selector switch must be turned back to off

before the engine will start.

3. Let the engine warm to operating temperature.

4. Hold the ground operation switch up while operating

the control toggle switches.

5. Hold the appropriate toggle switch in the desired

direction.

6. Release the function toggle switch to stop move-

ment.

7. Place the ground operation switch in the off position

when no functions are being operated.

Figure 8.2 – Lower Controls

Upper Controls

The upper controls may be used for driving the aerial

platform and positioning the booms and platform while

on the job.

Use the following procedure to operate machine func-

tions using the upper controls.

. At the lower controls, pull the emergency stop button

outward. Insert the key in the control selector and

turn the switch to the upper control position.

2. Enter the platform and securely close the gate.

3. Attach the fall restraint lanyard to one of the anchor

points.

4. Pull the emergency stop outward (refer to Figure

8.3).

Ground Operation

Switch

Emergency

Stop Button

Control Selector

Switch

Start Button

Engine/Emergency

Power Switch

This manual is related to the following products: