Chapter 4 – Safety Devices

TB60/66J – 0084030EE

7

Platform Overload Sensing System

All functions are stopped from the upper and lower

controls, when the platform overload limit is exceeded.

The horn will sound intermittently and the red overload

light (refer to Figure 4.7) will blink until the excess load

is removed from the platform. At that time, the machine

functions are again operational.

Figure 4.7 – Upper Controls

If the platform becomes significantly overloaded, or if

an upward force on the platform exceeds approximately

445 N (00 lbs), the system will enter into error mode,

stopping all functions from the upper and lower controls.

The horn will then sound constantly and the overload

light will stay illuminated at the upper and lower controls

(refer to Figures 4.7 and 4.8).

Figure 4.8 – Lower Control Panel

The system will remain in error mode until the excess

load is removed from the platform and the emergency

stop button or start switch is cycled off and back on,

resetting the system. At that time, the machine functions

are operational.

A

Caution

The emergency power system is for emergency

lowering and stowing only. The length of time the

pump can be operated depends on the capacity

of the battery. Do not use this system for normal

operation.

If the platform overload sensing system is tripped while

operating the machine or if the system is in error mode

and can not be reset, the emergency power system may

still be used for emergency machine operation.

A

Danger

The aerial platform can tip over if it becomes un-

stable. Death or serious injury will result from a

tip-over accident. Do not exceed the capacity values

indicated on the platform rating placard.

The overload sensing system is not active when the

machine is being driven with the booms in the stowed

position. This allows the machine to be driven without

the system sensing an overload due to rough ground

conditions.

To eliminate repeated tripping of the system during ma-

chine operation, there is a five second delay in machine

functions following:

• starting the engine.

• placing the drive/boom selector switch in the boom

position when the main boom is below horizontal

and fully retracted.

• removing excess load from the platform.

Engine Protection Systems

A constant tone alarm will sound to warn against high

engine temperature or low oil pressure.

The engine will shut-down if the operating temperature

exceeds a preset level or if the oil pressure is too low

for safe operation. An engine temperature gauge is on

the lower control panel (refer to Figure 4.8).

High Engine Temperature Alarm

If the oil exceeds 0°C (230°F) an alarm will sound and

the engine will shut off. Any time there is no alternator

current being produced, an alarm will sound and the en-

gine will shut off. This prevents high engine temperature

if the fan belt breaks.

Engine

Temperature

Gauge

Platform

Overload Light

Platform

Overload Light