8. EMERGENCY OPERATION

8 - 1

P/N 0191915

The following procedures are emergency
procedures only. Do not use them for normal
operation. Their purpose is to get the platform
and operator safely to ground when the TB126J
engine will not start or some other problem
keeps the platform from lowering in the normal
way.

T

EMERGENCY OPERATION FROM THE

PLATFORM-CONTROL BOX

Try Procedure A first. If Procedure A does not
work, use Procedure B.

z

z Procedure A

1. The BATTERY switch (1) must be ON.

2

3

4

2. The MASTER KEY SWITCH (2) must be ON.

3. The EMERGENCY STOP switch (3) must be
pulled out (on).

4. The SELECTOR SWITCH (4) must be set to
PLATFORM.

6

7

5

5. Set the EMERGENCY STOP switch (5) to on
(pulled up).

6. Set the ANTI-RESTART MASTER SWITCH
(6) to ON.

7. Step on the foot switch (7).

8

8. Pull down and hold the EMERGENCY
POWER OPERATION
switch (8).

9. Use the switches and/or controllers on top of
the platform-control box to move the platform as
desired.

NOTE: Boom movements will be slow and
have long lag times under EMERGENCY
POWER OPERATION
.

8. EMERGENCY OPERATION