Rcd/elcb ac outlet (option) 2-4, Flashing light (option) 2-4, Lanyard anchor points (option) 2-4 – Snorkel SR3370 User Manual
Page 22: Flashing light, 2-4, Lanyard anchor points, 2-4, Rcd/elcb ac outlet, 2-4, Rcd/elcb ac outlet (option) -4, Safety devices

n RCD/ELCB AC Outlet (option)
Figure 2.11 - RCD/ELCB AC Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at
the ground and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let. To re set the out let dis con nect the power tool
lead from the plat form box and re set the RCD at the
ground. If the prob lem per sists call a trained ser -
vice technician.
n Flashing Light (option)
The flash ing light alerts peo ple that the SR is pres -
ent and that the SR is mov ing. The light flashes at
about one flash per sec ond any time the SR en gine
is run ning. There is no ON/OFF switch for the flash -
ing light, it can not be turned off while the SR is run -
ning.
n Lanyard Anchor Points (option)
There are four an chors on the floor of the plat form,
one at the front of the roll-out deck, one at the back
of the plat form, and one on each side of the plat -
form.
NOTE
These anchors are not for lifting or tying down
the machine.
You should at tach your fall pro tec tion to the an -
chors if work rules re quire it.
page 2 - 4
Rev B
SR3370 & SR2770 – 12696A
2. Safety Devices
RCD
Power Input
Connector
Power Outlet
At Platform