Chapter 7 – controls danger, Caution, Lower controls – Snorkel S3219E-sn000017+ User Manual

Page 21: Battery disconnect

background image

S3219E/S4732E – 1500834

17

Lower Controls

The lower controls (refer to Figure 7.2) are located at

the rear of the chassis. Only platform functions can be

operated from the lower controls.

Figure 7.2 – Lower Controls

The following are located on the lower control panel:

Emergency stop button

Control selector/ground operation switch

Platform raise/lower switch

Emergency Stop Button

The emergency stop is a two-position red push button.

Push the button inward to disconnect power to all

control circuits.

Pull the button outward to restore power.

Control Selector/Ground Operation Switch

Insert the key into the control selector/ground operation

switch.

Turn the switch to the upper controls position to operate

the aerial platform functions from the upper controls.

In the center position, aerial platform functions will not

operate from the lower or upper controls.

Hold the switch downward continually in the lower con-

trols position to enable the platform raise/lower switch

functions. The switch is spring returned to the off position.

The upper controls will not operate while the control

selector is in the lower position.

Platform Raise/Lower Switch

The platform raise/lower switch is used to raise or lower

the platform. The switch is spring returned to the center

off position.

Hold the switch upward to raise the platform.



1500438

1500438

Chapter 7 – Controls

Danger

Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components, buildings, structures,

or other obstacles. Make sure all personnel stand

clear while operating the aerial platform.

Controls to position the platform are located on the

lower control panel on the chassis and on the upper

control panel in the platform.

Controls to drive the aerial platform are located on the

upper control panel only.

Battery Disconnect

The battery disconnect switch is at the rear of the platform,

below the entry step (refer to Figure 7.1).

Figure 7.1 – Rear of Chassis

The battery disconnect switch removes electrical power

from all electrically controlled functions when in the off

position.

Place the switch in the on position to operate any

electrically controlled function.

Caution

Only authorized personnel should operate the aerial

platform. Unqualified personnel may cause injury

to coworkers or property damage. Lock the battery

disconnect switch in the off position before leaving

the aerial platform unattended.

Lock the battery disconnect switch in the off position

to prevent unauthorized use of the aerial platform.

Emergency

Stop Button

Platform

Raise/Lower Switch

Control

Select/Ground

Operation Switch

Battery Disconnect Switch