Caution, Danger, Chapter 7 – controls – Snorkel S2033CE User Manual
Page 21
S2033 – 330003EE
17
Emergency Stop Switch
The emergency stop is a two-position toggle switch. Push
the red safety guard down over the toggle switch to dis-
connect power to all control circuits. Lift the guard and
push the toggle switch up to restore power.
Control Selector Switch
Insert the key into the control selector switch. Turn the
switch to the lower controls position to operate aerial
platform functions from the lower controls. The upper con-
trols will not operate while the control selector is in the
lower position.
Turn the switch to the upper controls position to operate
the aerial platform functions from the upper controls.
In the center position, aerial platform functions will not
operate from the lower or upper controls.
Platform Raise/Lower Switch
Pull up on the platform switch to raise the platform. Re-
lease the switch when the desired height is reached.
Push down on the switch to lower the platform. The low-
ering alarm will sound as the platform lowers.
Circuit Breaker Reset Button
A circuit breaker is located in the electrical power line of
the lower control panel. The circuit breaker protects the
wiring and components from electrical overload in case
of a short circuit or other fault.
A
Caution
A tripped circuit breaker indicates a malfunction in
the electrical system. Component damage can re-
sult if the cause of the malfunction is not corrected.
Do not operate the aerial platform if the circuit
breaker trips repeatedly.
Push the button to reset the circuit breaker.
Low Voltage Warning Light
When the voltage of the battery pack falls to a preset
level too low for proper machine operation the following
happens.
• The low voltage warning light turns on
• An alarm sounds
• The platform will not raise
Lower the platform to the stowed position when the warn-
ing light is on and the alarm is activated. Drive to a bat-
tery recharging area and fully recharge the battery pack
before returning the aerial platform to service.
A
Danger
Pinch points may exist between moving compo-
nents. Death or serious injury can result from be-
coming trapped between components, buildings,
structures, or other obstacles. Make sure all person-
nel stand clear while operating the aerial platform.
Controls to position the platform are located on the lower
control panel on the chassis and on the upper control
panel in the platform. Drive controls are located on the
upper control panel only.
Battery Disconnect Switch
The battery disconnect is located on the lower control
panel (refer to Figure 7.1).
Figure 7.1 – Battery Disconnect Switch
The battery disconnect switch removes electrical power
from all electrically controlled functions when in the off
position. Place the switch in the on position to operate
any electrically controlled function.
A
Caution
Only authorized personnel should operate the aerial
platform. Unqualified personnel may cause injury
to coworkers or property damage. Lock the battery
disconnect switch in the off position before leaving
the aerial platform unattended.
Lock the battery disconnect switch in the off position to
prevent unauthorized use of the aerial platform.
Lower Controls
The lower controls (refer to Figure 7.1) are located on the
right side of the chassis. Only platform functions can be
operated from the lower controls. The following controls
are located on the lower control panel.
• Emergency stop switch
• Control selector switch
• Platform raise/lower switch
Chapter 7 – Controls
Emergency Stop Switch
Control Selector Switch
Platform Raise/Lower Switch
Battery Disconnect Switch
Low Voltage
Warning Light
Circuit Breaker
Reset Button