Emergency Stop Switch

The emergency stop is a two-position toggle switch. Push

the red safety guard down over the toggle switch to dis-

connect power to all control circuits. Lift the guard and

push the toggle switch up to restore power.

Control Selector Switch

Insert the key into the control selector switch. Turn the

switch to the lower controls position to operate aerial

platform functions from the lower controls. The upper con-

trols will not operate while the control selector is in the

lower position.

Turn the switch to the upper controls position to operate

the aerial platform functions from the upper controls.

In the center position, aerial platform functions will not

operate from the lower or upper controls.

Platform Raise/Lower Switch

Pull up on the platform switch to raise the platform. Re-

lease the switch when the desired height is reached.

Push down on the switch to lower the platform. The low-

ering alarm will sound as the platform lowers.

Circuit Breaker Reset Button

A circuit breaker is located in the electrical power line of

the lower control panel. The circuit breaker protects the

wiring and components from electrical overload in case

of a short circuit or other fault.

A

Caution

A tripped circuit breaker indicates a malfunction in

the electrical system. Component damage can re-

sult if the cause of the malfunction is not corrected.

Do not operate the aerial platform if the circuit

breaker trips repeatedly.

Push the button to reset the circuit breaker.

Low Voltage Warning Light

When the voltage of the battery pack falls to a preset

level too low for proper machine operation the following

happens.

• The low voltage warning light turns on

• An alarm sounds

• The platform will not raise

Lower the platform to the stowed position when the warn-

ing light is on and the alarm is activated. Drive to a bat-

tery recharging area and fully recharge the battery pack

before returning the aerial platform to service.

A

Danger

Pinch points may exist between moving compo-

nents. Death or serious injury can result from be-

coming trapped between components, buildings,

structures, or other obstacles. Make sure all person-

nel stand clear while operating the aerial platform.

Controls to position the platform are located on the lower

control panel on the chassis and on the upper control

panel in the platform. Drive controls are located on the

upper control panel only.

Battery Disconnect Switch

The battery disconnect is located on the lower control

panel (refer to Figure 7.1).

Figure 7.1 – Battery Disconnect Switch

The battery disconnect switch removes electrical power

from all electrically controlled functions when in the off

position. Place the switch in the on position to operate

any electrically controlled function.

A

Caution

Only authorized personnel should operate the aerial

platform. Unqualified personnel may cause injury

to coworkers or property damage. Lock the battery

disconnect switch in the off position before leaving

the aerial platform unattended.

Lock the battery disconnect switch in the off position to

prevent unauthorized use of the aerial platform.

Lower Controls

The lower controls (refer to Figure 7.1) are located on the

right side of the chassis. Only platform functions can be

operated from the lower controls. The following controls

are located on the lower control panel.

• Emergency stop switch

• Control selector switch

• Platform raise/lower switch

Chapter 7 – Controls

Emergency Stop Switch

Control Selector Switch

Platform Raise/Lower Switch

Battery Disconnect Switch

Low Voltage

Warning Light

Circuit Breaker

Reset Button