beautypg.com

Location, Bulkhead mounting (el model) – Micropump EagleDrive ELE User Manual

Page 9

background image

9

DOC No: 8540 REV D

The product should be located with the inlet below or even with the liquid level of the fluid

supply. The product can be mounted in any position. Ensure that there is adequate space

for operation, inspection and maintenance.

Location

Pump head or adaptor cannot support the weight of the motor. Ensure

the motor is adequately supported by the foundation and/or mounting

bracket.

The foundation must be capable of supporting the combined weight of

the pump and motor and provide a rigid support.

Bulkhead Mounting (EL Model)

If mounting the pump/EagleDrive assembly through a bulkhead, insert the bulkhead

o-ring (1) into the groove in the face of the housing (3). Position the adaptor flange (2)

through the bulkhead hole so that it does not interfere with the sealing of the bulkhead

hole. Secure the pump/EagleDrive assembly using four screws, nuts, and washers as

needed. Tighten screws evenly and in an alternating pattern.

O-Ring 2-040 described below is necessary to ensure bulkhead is

sealed.

CAUTION

Ш 68.3 ± 1[2.70 ± .04]

70 2.76

Ш 5[.20]

1

3

2

This manual is related to the following products: