The two fault signals provide diagnostic feedback to the user’s control system. These use
the common ground to provide HI or LOW signals. When both Fault Signals indicate HI, the
EagleDrive is operating normally (no faults detected). Signals are driven with 5.6kohm pull-up
resistors to the internal 5V and should be monitored with a high impedance device (R

load

>

100kohms).

Fault Signal Out

Fault

Signal 1
Lead 8

Brown

Fault

Signal 2
Lead 7

Blue

Fault

Description

Drive

Condition

Reason for

Fault

Remedy

0

0

Under

Voltage

Disabled

Voltage

supply less

than 8.5V

Ensure proper supply voltage,

check power and ground

connections

0

0

Over

Temperature

Operating

Internal

component

temperature

greater than

170º C

Reduce load or increase

cooling

0

0

Logic Fault

Disabled

Drive cannot

locate the

magnets

inside the

pump

Ensure pump is correctly

attached to EagleDrive

1

0

Internal Short

Disabled

Drive

components

have failed

Reset EagleDrive by

disconnecting and restoring

power supply connection,

if problem persists, contact

Micropump for a replacement.

0

1

Low Load

Current

Operating

Drive

components

have failed

Reset EagleDrive by

disconnecting and restoring

power supply connection,

if problem persists, contact

Micropump for a replacement.

1

1

None

Operating

No Fault

CAUTION

Do not short Fault Signals to ground or EagleDrive will not operate properly.