beautypg.com

Manual control configuration – Micropump EagleDrive ELE User Manual

Page 16

background image

16

DOC No: 8540 REV D

To maintain protection of internal drive controller, your external

potentiometer should be fitted with appropiate Insulation.

Manual Control Configuration

Manual Control
Install a resistor (sized according to your voltage supply input) across the red Power
In and black Common lead wires. The potentiometer wiper is connected to the yellow
Speed Input lead wire. To increase speed, rotate the potentiometer to increase voltage to
the control line. To decrease speed, rotate the potentiometer to decrease voltage to the
control line.

CAUTION

Resistor (38 KOHM)

VISHAY CMF5038K300FHEB

Potentiometer (10 KOHM)

VISHAY P16NP103KAB15

Recommended Parts (24 VDC Mains)

RED

YELLOW

BLACK