DOC No: 8540 REV D

Maintenance

Excessive wear to the pump can result in driven magnet rub on the

magnet cup. This can generate high surface temperatures or degrade the

capability of the pressure boundary. Remove the pump from service and

replace or repair if pump performance degrades significantly or the pump

becomes noisy.

Ensure that heavy deposits of dust are not allowed to accumulate. Clean

the pump periodically.

The pump cannot be drained completely, a certain amount of liquid will

remain in the magnet cup area. Ensure that the pump is either flushed

with a suitable flushing agent or precautions are taken against the effect

of any remaining liquid during servicing. When the pump has been

handling flammable, toxic or hazardous fluid, the pump internals must

be properly decontaminated by suitably qualified personnel. The Material

Safety Data Sheet for the pumped liquid must be referred to for correct

procedures and precautions to be followed when handling the liquid.

Micropump EagleDrive motors are designed to be maintenance free and require no

adjustments. To ensure the motor or pump/motor assembly retains optimum performance

maintain the fluid circuit to keep filters clean and prevent abrasive solids from passing

through the pump.

A program that includes periodic monitoring of your Micropump product is

recommended to provide timely detection and assessment of any problem.

NOTE

Magnet Decoupling

The EagleDrive pump/motor combinations do not decouple. If pump load becomes

excessive, current limiting in the controller prevents motor overload. Additional protection

is provided by a thermal sensor which shuts down the drive if the internal temperature

exceeds a preset value.