beautypg.com

Lukas P 660 SG User Manual

Page 19

background image

19

Visual inspection

Hydraulic unit
• are all hydraulic connections still tightened,
• generally sealed, no leaks present (oil "sweat" has no effect on the operation),
• is damage visible on the motor, hydraulic components or the housing,
• are identi¿ cation plate, all control decals, instruction decals, labels and warnings

present and legible,

• are all covers (e.g. exhaust cover) in place and undamaged,
• are all À uid levels within the prescribed tolerances,
• is the recoil starter in proper working condition and undamaged,
• couplings easy to connect,
• dust caps in place,
• are all required accessory parts (such as spark plug, spark plug wrench and fuel can)

present.

Operational check
• no suspicious noises,
• tests at maximum load.

(Recommendation: Use the LUKAS test set, including test instructions, for the functional
check).

Additional maintenance measures on the motor:

Every 50 operating hours you must perform the following maintenance measures:

• Wash the air ¿ lter element. More frequently when used in dirty or dust surroundings.
• Check the spark plug and clean it, if necessary.

Every 100 operating hours you must perform the following maintenance measures:

• Change the motor oil. More frequently when used in dirty or dust surroundings.

Every 200 operating hours you must perform the following maintenance measures:

• Set the spark plug gap.
• Clean the fuel ¿ lter.

Every 500 operating hours you must perform the following maintenance measures:

• Replace the spark plug and ¿ lter element.
• Clean and/or adjust the carburettor, tappet clearance, valve seat and cylinder head.

Every 1,000 operating hours or every 2 years you must perform the following maintenance
measures:

• Check the starter.
• Replace the rubber assembly block of the motor.
• Inspect the motor.
• Replace the fuel line.

NOTE:
The ¿ rst motor oil change must be carried out after 20 working hours. Subsequent
oil changes each are due after 100 hours.