36

Fault

Check

Cause

Solution

Connected rescue
device does not
reach its

¿ nal

position

Check hydraulic
À uid volume in
hydraulic tank

Insuf

¿ cient À uid in the

hydraulic tank

Top up hydraulic

À uid

to the maximum

¿ lling

level

Caution! Before
topping up the rescue
equipment, return to
the base position!

Usable hydraulic

À uid

volume of the unit is
insuf

¿ cient

Use a different rescue
device with a demand
quantity below the
maximum usable
quantity of the unit

Connected rescue
device does not
reach its speci

¿ c

performance data

Maximum permitted
operating pressure
of the pump is not
reached

Have the pressure
limiting valve reset or
repaired by authorised
dealer or directly by
LUKAS

Pump block defective

Have repaired by
authorised dealer or
directly by LUKAS

Connected unit
defective

Recti

¿ cation see

operating instructions of
the connected unit

During function test:
A pressure gauge
installed between the
rescue equipment
and the hydraulic
power unit does
not indicate the
maximum operating
pressure of the
equipment.

Check the details
of the rescue
device

The operating pressure
of the connected
rescue device is locked
internally

No repair or fault
recti

¿ cation required

Connected rescue
device is defective

Consult the separate
operating manual for
the connected rescue
device

Hydraulic unit defective Have repaired by

authorised dealer or
directly by LUKAS