beautypg.com

Operation – Lukas P 630 SG User Manual

Page 20

background image

20

7.2.3 Commissioning (after the fi rst fi lling or prior to use)

1. Check the

À uid level of the engine oil, the hydraulic À uid and the fuel tank. Top up if

necessary. For precise reading off of the

À uid levels and for ¿ lling, the hydraulic unit

should be as level as possible.

2. Now connect the extension hoses and/or hose reels (unless already connected to the unit)

and/or couple the rescue equipment.

Before starting the combustion engine, check that the fuel tank is full and that the engine oil
level is within the permitted tolerances. If necessary, top up the relevant

À uid.

1. Open the petrol tap
2. Set the ON/OFF switch to the ON position.
3. Move the lever from switching position A to switching

position B (choke) when starting cold

4. Pull the cable-starter.
5. When the motor is running, switch the lever back to

position A.

For the detailed procedure for starting the
combustion engine, please see the
separate operating instructions of the engine manufacturer!

ATTENTION!
The control levels on the hydraulic power unit should always be switched to the
neutral position (de-pressurised) prior to starting the engine in order to prevent
unwanted movements of connected hydraulic equipment and to start the power
unit without hydraulic load.

B

A

8.1 Starting the engine

8. Operation