SERVICE (cont.)

SOLENOID (WATER) ON/OFF SWITCHES

FIG.18 SOLENOID (WATER) ON/OFF SWITCHES

P1521

Location:

The solenoid (water) ON/OFF switches are located

on the switch mounting plate inside the autofill box on

the right side.

Test Procedure:

1. Disconnect the dispenser from the power source.

2. Disconnect the wires from the switch to be test-

ed.

3. Check for continuity across the terminals on the

switch when it is held in the on position. Continuity

must not be present across these terminals in the

released position.

If continuity is present as described, refer to Fig. 19

and reconnect the wires to the switch.

If continuity is not present as described, replace the

switch.

FIG. 19 SOLENOID (WATER) SWITCH

TERMINALS

P1524

BLK from Pump Switch #2

BLK to Pump Switch #1

BLU to Test/Operate Switch

BLU to to Solenoid #1

BLK from Main ON/OFF Switch

BLK to Pump Switch #2

VIO to Test/Operate Switch

VIO to Solenoid #2

#1

AFPO-2 & 3

#2

AFPO-2 & 3

BLK from Pump Switch #3

WHI/VIO to Test/Operate Switch

WHI/VIO to Solenoid #3

#3

AFPO-3 ONLY

Removal and Replacement:

1. Remove the wires from the switch terminals.

2. Compress the clips inside the autofill box and gently

push the switch through the opening.

3. Push the new switch into the opening and spread

the clips to hold switch in the autofill box.

4. Refer to Fig. 19 when reconnecting the wires.

41093 040408