SERVICE (cont.)

PUMP (FLAVOR) ON/OFF SWITCHES

Location:

The pump (flavor) START switches are located on

the switch mounting plate inside the autofill box on

the right side.

Test Procedure:

1. Disconnect the dispenser from the power

source.

2. Disconnect the wires from the switch to be

tested.

3. Check for continuity across the terminals on the

switch when it is held in the on position. Continuity

must not be present across these terminals in the

released position.

If continuity is present as described, reconnect the

wires to the switch.

If continuity is not present as described, replace the

switch.

FIG.12 PUMP (FLAVOR) START SWITCHES

FIG. 13 PUMP (FLAVOR) SWITCH TERMINALS

P1521

P1524

BLK from Solenoid Switch #1

BLK to Test/Operate Switch

RED/BLK to Test/Operate Switch

YEL to Pump #1

BLK from Solenoid Switch #1

BLK to Solenoid Switch #2

BRN/BLK to Test/Operate Switch

ORN to Pump #2

#1

AFPO-2 & 3

#2

AFPO-2 & 3

BLK from Solenoid Switch #2

BLK to Solenoid Switch #3

WHI/RED to Test/Operate Switch

RED to Pump #3

#3

AFPO-3 ONLY

Removal and Replacement:

1. Disconnect the dispenser from the power

source.

2. Remove the wires from the switch terminals.

3. Compress the clips inside the autofill box and

gently push the switch through the opening.

4. Push the new switch into the opening and spread

the clips to hold switch in the autofill box.

5. Refer to Fig. 13 when reconnecting the wires.