System Overview

The Series II Pressure Governor is a computer controlled throttle and pump interlock monitor-
ing system. The system uses a linear throttle actuator and a set of toggle switches to control
engine RPM. It will maintain a selected pump discharge pressure or engine speed in re-
sponse to the selected mode and desired operating parameter. Pressure sensing is done
with a 0-300 PSI transducer and RPM is monitored with a magnetic pick-up.

There are seven (7) major components:

ECU Microsentry Unit

PN 108082

PSI

Transducer

PN 100581

Linear Actuator

PN 101702

RPM Sensor

PN 102902

Actuator Control Module

PN 100328

Control Head

PN 100478

Harness

PN100454-D

In PSI Mode, the system monitors the pressure transducer and changes the actuator position
to maintain the set pressure. In essence, cruise control for the pump. In RPM Mode, the
system maintains a constant engine RPM regardless of varying torque loads or pressure.
Both modes are dependent on the capability of the engine to respond to changes.

The system has diagnostic capability through the Control Head Assembly and requires a
“diagnostic pigtail” for access. The system stores fault codes for key components and these
are also accessed through the Control Head.

Installation requirements are 12 Volt power with circuit protection and a safety interlock sys-
tem.