beautypg.com

System operation, Ystem, Peration – Class1 Engine status center User Manual

Page 8

background image

8

S

YSTEM

O

PERATION

ESC Power

A-1 circuit
A-2 circuit

These are the power and ground inputs for ESC operation and they also
provide system voltage information to the ESC for display.

ESC Data

A-3 circuit
A-4 circuit

Engine information is received electronically on the J-1587 data bus.

Check Engine Warning

B-4 circuit

This input (ground) must be active for a check engine warning on all
engines except Detroit Diesel

.
Auxiliary Input

B-5 circuit

This input (ground) is used for an auxiliary device active or warning mes-
sage (configurable by the OEM).

Alarm Output

B-9 circuit

This output (ground) should be active when TEST LTS is selected form the
menu. The alarm can be deactivated during operation by the user.

PTO HRS

B-10 circuit

This input must be active (+ 12 VDC) when the PTO is engaged to log hours
and display the PTO ENGD message.

Auxiliary Hours

B-11 circuit

This input (+ 12 VDC) can be used for any device that you want to monitor.
The message is configurable by the OEM.

Low Fuel

B-12 circuit

This input (ground) will display a LOW FUEL alert message when active.