beautypg.com

Test, Batt, Alar – Class1 ENFO IV User Manual

Page 10

background image

Enfo IV (109050) 090303

– 10 –

Class 1

Entering the menu

The Enfo IV’s alarm silence button is used to enter the menu. Press and hold the

alarm silence button for 5 seconds. The Engine RPM display will show “SEL”,

the Oil Pressure display will show “----“, and the Engine Temp display will show

the “time remaining” counter which will begin counting down seconds starting at

5.

Press the alarm silence button to scroll through the menu items. When the

desired menu item is shown allow the “time remaining” counter to reach zero.

Each time the alarm silence button is pressed the “time remaining” counter will

be reset to 5.

Menu Items

----

Exit the menu.

TEST

Turns on all of the display segments and activates the

alarm.

BATT

View the auto-selected voltage range.

ALAR

View all of the alarm trip points (they will be displayed

in their associated window).