Pin #

OBD1 Honda / Acura

AEM EMS 30-6040

I/O

Availability

B1

Power Source 2

+12V Switched

Both

Dedicated

B2

Logic Ground 2

Power Ground

Both

Dedicated

B3

---

Coil 3

Output Avail, Rising Edge Trigger Coil Out

B4

---

Coil 4

Output Avail, Rising Edge Trigger Coil Out

B5

A/C Switch Signal

Switch 3

Input

PnP for A/C Switch Signal

B6

---

Coil 2

Output Avail, Rising Edge Trigger Coil Out

B7

---

ADCR13

Input

Avail, 0-5 Volt Input, 100k pull up

B8

Power Steering Pressure Switch

Switch 5

Output

Avail, Switched Input

B9

Starter Switch Signal

+12V When Cranking

Input

Dedicated

B10

Vehicle Speed Sensor

T3 (Vehicle Speed)

Input

PnP for Vehicle Speed Sensor

B11

CYP +

Cam Sensor

Input

Dedicated, PnP 1 pulse per cycle

B12

CYP -

Timing Ground

Output

Dedicated

B13

TDC +

T4 (Spare Speed)

Input

Avail, Magnetic Speed Sensor

B14

TDC -

Timing Ground

Output

Dedicated

B15

CKP +

Crank Sensor

Input Dedicated, PnP 24 pulses per cycle

B16

CKP-

Timing Ground

Output

Dedicated


Pin #

OBD1 Honda / Acura

AEM EMS 30-6040

I/O

Availability

C1

---

+12V Switched

Input

Dedicated

C2

---

CAN1H

---

Dedicated

C3

---

Tach Output (LS7)

Output

Avail, Switched Gnd, 1.5A max

C4

---

Low Side Driver 9

Output

Avail, Switched Gnd, 1.5A max

C5

---

Switch 6

Input

Avail, Switched Input

C6

---

Low Side Driver 1

Output

Avail, Switched Gnd, 1.5A max

C7

---

Switch 1

Input

Avail, Switched Input

C8

---

IDLE #3

Output

Avail, Ground / +12V, 1.5A max

C9

---

ADCR14

Input

Avail, 0-5 Volt Input, 100k pull up

C10

---

PW 2

Output

Avail, Boost Control Solenoid

C11

---

High Side Driver 2

Output

Avail, +12V, 1.5A max

C12

---

Switch 2

Input

Avail, Switched Input