AEM 30-3020M Water Methanol Failsafe Device User Manual
Page 4
![background image](/manuals/546613/4/background.png)
Page 4
Water/Methanol Failsafe Configuration Tab
This is the section where the flow monitoring and alarm output functionality of the Water/Methanol Failsafe is configured.
Flow vs. Injection Graph
Description
Displays flow vs. injection percentage data points. Flow points will be populated live whenever the PC is connected to the
Water/Methanol Failsafe and injection is occurring. The current injection percentage and flow rate values are shown live
on the right side of the graph. This is also where the high and low flow limit lines are established.
Graph
Button
Description
Auto Scale
Scales the graph down to best resolution; the graph automatically scales up in the event flow
data is collected beyond the highest shown flow value
Auto Set Limits
Automatically sets the upper and lower flow limit lines based on an average of the collected flow
data points
Reset Limits
Resets the upper flow limit line to max and the lower flow limit line to zero
Clear Graph
Clears all the displayed flow data points from the graph; does not clear stored flow data from
logger
Logger
Button
Description
Download Log
Downloads all the collected flow data that is stored in the logger; will prompt to save log to disk;
log files saved as .daq for direct viewing in AEMdata program
Clear Log
Clears all stored flow data from the logger