Pilot programming, Personalizing – J.P. Instruments EDM 760 Pilots Guide User Manual
Page 41

complete, simultaneously hold the STEP and LF buttons for five 
seconds.
Personalizing
Pilot Programming
You can program the automatic indexing rate (1-9 seconds or 0 = don’t 
auto-index), the temperature display (°F or °C) and the EGT resolution (1 
or 10°). To start the Pilot Programming Procedure, simultaneously hold 
the STEP and LF buttons for five seconds. You will see the word 
PROGRAM for two seconds and then the sequence shown in the chart 
below. Tap the STEP button to advance to the next item in the list. Tap 
the LF button to select alternate values of that item. The shaded areas in 
the chart below pertain only to the Fuel Flow Option.
S
el
ec
t
sw
itc
h
Tap STEP 
to advance 
to the next
item
Tap LF to
sequence
through these
values
Comments
T, F, A
PROGRA
M
Stays on for two seconds.
T, F, A
FUEL ? 
N
N Y
Y—Yes—to change fuel status (see 
page 29)
T, A
RATE 4
0 9
Indexing rate in the Automatic 
Indexing Mode. Selecting 0, disables 
the Automatic Indexing Mode.
T, A
OAT 
F
OAT F
OAT
C
OAT readings in °F or °C.
Special mode: To calibrate the OAT 
±
10°, hold both the STEP and LF
buttons simultaneously for five 
seconds, which will proceed to the 
next step. 
For Your Safe Flight
Page 37
