Pilot programming, Personalizing – J.P. Instruments EDM 760 Pilots Guide User Manual
Page 41

complete, simultaneously hold the STEP and LF buttons for five
seconds.
Personalizing
Pilot Programming
You can program the automatic indexing rate (1-9 seconds or 0 = don’t
auto-index), the temperature display (°F or °C) and the EGT resolution (1
or 10°). To start the Pilot Programming Procedure, simultaneously hold
the STEP and LF buttons for five seconds. You will see the word
PROGRAM for two seconds and then the sequence shown in the chart
below. Tap the STEP button to advance to the next item in the list. Tap
the LF button to select alternate values of that item. The shaded areas in
the chart below pertain only to the Fuel Flow Option.
S
el
ec
t
sw
itc
h
Tap STEP
to advance
to the next
item
Tap LF to
sequence
through these
values
Comments
T, F, A
PROGRA
M
Stays on for two seconds.
T, F, A
FUEL ?
N
N Y
Y—Yes—to change fuel status (see
page 29)
T, A
RATE 4
0 9
Indexing rate in the Automatic
Indexing Mode. Selecting 0, disables
the Automatic Indexing Mode.
T, A
OAT
F
OAT F
OAT
C
OAT readings in °F or °C.
Special mode: To calibrate the OAT
±
10°, hold both the STEP and LF
buttons simultaneously for five
seconds, which will proceed to the
next step.
For Your Safe Flight