J.P. Instruments EDM 760 Pilots Guide User Manual
Page 14

Measurement Indexing—without Fuel Flow Option
The EDM-760 steps through the engine measurements in a specific
sequence. Listed below is the indexing sequence, measurement description
and example of the digital display.
Measurement
Example
Comments
Voltage, System Bus
Outside Air
Temperature
I4.2
8I BAT
OAT
Battery voltage and OAT °F
or °C
Difference between
hottest and coolest
EGT
80
EGT
52
DIF
DIF
Dot indicates most widely
deviating cylinder
EGT, CHT
I340
I430
376
385
EGT, left, CHT, right. Dot
indicates cylinder
TIT, Turbine Inlet
Temperature
I370
I450
TIT
TIT
Oil Temperature
I 7 7
I80
OIL
OIL
TIT #2 Second Turbine
Inlet Temperature
I450
I460
T I2
T I2
Only one of these three
options may be installed in
the aircraft
Carburetor Temperature
20
25
CRB
CRB
Page 10
Engine Data Management