beautypg.com

Installing the high flow suction tube, c – PureFlow AirDog FP-150 - 6.4L Ford 2008-2010 User Manual

Page 16

background image

16

PureFlow AirDog

AirDog

®

FP-100 & FP-150 Ford PowerStroke 2008 6.4L

Section 5-D High Flow Suction Tube

INSTALLING THE HIGH FLOW SUCTION TUBE, C

ont’d.


5D-5. Measure and cut the suction tube to a length that will allow approximately 1/8”

clearance off the bottom of the tank. It is suggested to form the end of the tube similar to
Figure 38.

Figure 35

5D-6. Lubricate the bulkhead fitting with motor oil. Pressing firmly, insert the suction tube

assembly into the grommet. Be sure the bulkhead fitting is completely seated in the

grommet.

Figure 36

Figure 37




5D-7. Re-install the Collection basket.

Re-install the factory return line to the proper

port of the Collection basket before the tank

is fully re-installed.

Figure 38


5D-8. Connect the end of the “Suction Hose Assembly” to the bulk head fitting while it is

easily accessible. A “click” will be heard when it is properly installed.

5D-9 Any excess fuel hose can be addressed by routing the hose in a fashion to take up

the extra length, or a section of the hose can be removed. Push lock splices have

been included if you choose to remove the excess hose


This manual is related to the following products: