Caution, Emergency operations – SkyTrak 6036 Tier II Operation Manual User Manual
Page 91

Emergency Operations
85
Model 6036
4. Position the towing vehicle in place. Attach any chains needed to
secure the disabled vehicle.
5. Attach a remote portable hydraulic pressurizing unit to the parking
brake gauge port (3) on the secondary function manifold (4)
mounted on the inside wall of the frame (5) on the left side next to
the transmission.
6. Turn the key switch to the ON position (with the engine not run-
ning), release the park brake (park brake switch OFF), and have an
operator seated in the seat.
7. Pressurize the park brake with the pressurizing unit. Close the
pump needle valve on the pressurizing unit.
CAUTION:
DO NOT exceed 575 psi (40 bar) when pressur-
izing the park brake. Applying too much pressure may damage
the brake seals.
4
OA1230
Front
3
5