General maintenance, Air cleaner & restriction indicator – SkyTrak 6036 Tier II Operation Manual User Manual
Page 114

108
Model 6036
General Maintenance
NEVER operate the vehicle without the air cleaner assembly and both filters
in place.
A. Filter Check
(10 Hour Intervals)
1. Ground the carriage, place the travel select lever in (N) NEUTRAL,
move the neutral lock lever to NEUTRAL LOCK position, engage
the parking brake switch and shut off the engine.
2. Unlock and open the left rear engine access door to access air
cleaner restriction indicator (1). Check indicator. If red band (2) has
appeared, filter must be replaced.
NOTE: Depress button (3) on top of indicator to reset indicator after servic-
ing element.
IMPORTANT! Only remove canister cover to service the elements
as restriction indicator indicates or during scheduled maintenance intervals.
Excessive access to check an element can lead to premature element
failure and increase the possibility of dirt entering the engine.
2. Air Cleaner & Restriction Indicator
10
OF1190
OH2660
OH3370
1
2
3