6 Installation
6 -1. Installation diagram
Confirmation
Please refer to how to install gauges, displays, and sensors of each manual
as well as this manual.
The meter wire can be connected to both two connectors of METER OUTPUT.
Up to 7 gauges and displays in all can be connected to one control unit. (Ex. If
7 gauges are connected to one line, none can be connected to the other line.
If three gauges are connected to one line, up to 4 gauges can be connected to
the other line.)
Do not connect more than one gauge of the same variety. (Ex. You can NOT
connect 2 turbo gauges together.) However, several ZDs can be connected.
Sensor Wires
→Sensors
→Connect to vehicle
Power source wire
→Connect to vehicle
Switch unit
Meter wire
Meter wire
CR
ZD
CR
CR
BF
ZD
ADVANCE
Control Unit
BF
6 -2. Procedure
1. Confirm the contents.
⇒ Please refer to operation manuals included with components and each
gauge.
2. Confirm and prepare the necessary parts for installation.
⇒ Refer to the operation manual included with each gauge.
Please purchase commercially available attachment parts.
3. Confirm the location of the power source(Battery, GND, IGN, ILM) and the
sensor installation.
4. Disconnect the negative(-) battery terminal.
5. Connect the power supply wire to vehicle.
⇒ Refer to 6 -3. How to solder・How to use the solderless connectors.
Warning
Do not connect the IGN wire to the ACC (power source for accessory) wire.
Failure to do so way lead to a malfunction or accident.
6. Connect the power supply wire to the control unit. Connect the negative
battery terminal and turn the ignition on. Then confirm DC SOURCE LED
lights up, which is on the front of the control unit.
Confirmation
If the power source wire is wired incorrectly, LED won't light. If LED doesn't
light, please confirm wiring again.
7. Disconnect the negative battery terminal and install each sensor.
⇒ Refer to the operation manual included with each gauge.
8. Connect the sensor and the sensor wire. Then connect to the control unit.
52
53