3. When the

R

button is pressed, the number of cylinders changes

into1 → 2 → 3 → 4 → 5 → 6 → 8. When the

M

button is pressed,

the number of cylinders changes into 8 → 6 → 5 → 4 → 3 → 2 → 1. For
example, when the number of cylinders 1 is selected, the needle pointer
points to 1000rpm when the number of cylinders 4 is selected, the needle
pointer points to 4000rpm. Please set the number according to your vehicle.

4. After completion of setting, return the slide switch to

U

or

M

.

7 -5. Setting Tachometer response mode (slide switch position:

L

)

If tachometer has been installed, please set the response of Tachometer.
You have 3 types to choose from.
factory default setting: Position 1

If ZDs are installed as well, settings for tachometer need to be done in Sys-
tem Setup Mode of ZD. The settings of ZD are applied to other tachometers
connected to the ADVANCE System. Refer to ZD manual for setting.

By checking needle pointer movement , adjust the response speed of needle
pointer.

Position 1

faster

1000rpm

Position 2

middle

2000rpm

Position 3

slower

3000rpm

1. Set the slide switch to

L

.

2. If the

L

button is pressed long, the gauge shifts to Setting the

number of cylinders mode. The peak and warning LEDs on tachometer blink
alternately.
If ZDs are installed, the system moves into System Setup Mode of ZD not
tachometer setting mode. LEDs on the gauge doesn't blink. When the
tachometer is not installed, the system does not shift to Setting numbers of
cylinders mode or Setting Tachometer response mode.

3. If the

L

button is pressed long during Setting the number of

cylinders mode, the gauge shifts to Setting Tachometer response mode.
The peak and warning LEDs in the gauge are lighted up.

4. If the

R

button is pressed, the position changes into 1 → 2 → 3. If

the

M

button is pressed, the position changes into 3 → 2 → 1.

 1000rpm, 2000rpm and 3000rpm indicate Position 1, Position2 and posi-

tion3 respectively.

5. Return the slide switch to

U

or

M

.

7 -6. Setup mode (slide switch position :

L

)

By setting the optional warning value, when the gauge reaches or exceeds the
value set for warning, the warning LED on the gauge goes on ( in case of oil
pressure and fuel pressure, when the gauge reaches or falls below the value
set for warning, the warning LED goes on).
If ZDs are installed, warning setting is displayed on ZD display.
It is possible to change the illumination color of each gauge. Warning values
for gauges and ZDs are set at the same time.
Illumination color for CR gauges can be selected from 2 colors. Illumination
color of BF and ZD can not be changed.

Warning factory default settings

Setting range

Gauge

default setting Unit Minimum Maximum Lighting condition

Turbo2.0

100

kPa

-100

200

set value and above

Turbo1.2

100

kPa

-100

120

set value and above

In-Mani Press

10

kPa

-100

20

set value and above

Tachometer

7000

rpm

300

9000

set value and above

Oil Press

120

kPa

0

1000

set value and below

Fuel Press

150

kPa

0

600

set value and below

Oil Temp

125

50

150

set value and above

Water Temp

105

20

120

set value and above

Exhaust Temp

850

200

1100

set value and above