beautypg.com

BNC 835-M User Manual

Page 47

background image

 

47 
 

Model 835-M Programmer’s Manual V1.1 2011

:SYSTem Subsystem

Command

Parameters

Unit

(default)

Remark

:SYSTem:ERRor[:NEXT]?

:SYSTem:ERRor:ALL?

:SYSTem:PRESet

V0.4.1

:SYSTem:VERSion?

V0.4.1

:SYSTem:LOCK

V0.4.1

:SYSTem:LOCK:RELease

V0.4.1

:ERRor?

:SYSTem:ERRor[:NEXT]?

Return Parameters: Integer error number

Query command is a request for the next entry in the instrument’s error queue. Error messages in the
queue contain an integer in the range [–32768, 32768] denoting an error code and associated
descriptive text.

:ERRor:ALL?

:SYSTem:ERRor:ALL?

Return Parameters: List of integer error number

Query command is a request for the all entries in the instrument’s error queue. Error messages in the
queue contain an integer in the range [–32768, 32768] denoting an error code and associated
descriptive text. This query clears the instrument’s error queue.

:PRESet

:SYSTem:PRESet

Resets most signal generator functions to factory- defined conditions. This command is similar to the
*RST command.

:VERSion?

:SYSTem:VERSion?

Returns the SCPI version number that the instrument software complies with [1999.0]

:LOCK

:SYSTem:LOCK

Locks (disables) front panel control.

:LOCK:RELease

:SYSTem:LOCK:RELease

Unlocks (enables) front panel control.