Component Identification, Part Number, and Function
4
Control Reset Switch (570456)
Powers up the SmartBox
™
for heating zone and allows the
producer to reset the control back to day 1 for start of new
cycle. Position from On to Off, then back to On.
Fuses
Used for protection of the programmable controller and the
variable rate gas control valves.
Fuse for Forced Air heaters: 572812
Fuse for Incoming Power and Radiant Brooders: 572918
Fuse Holders
Secures the fuse into position within the electrical circuit.
Fuse holder with 1/4 in. male tabs:572809
Fuse holder with 3/16 male tabs: 572808
Indicator Lights
Green: (26392) Indicates which heat zone is in operation
Amber: ( 572813) Indicates heat cycle complete
Red: (571333) SmartBox
™
temperature sensor failure
Programmable Controller (572917)
Micro-processor used for the operation of the SmartBox
™
system and operation of the signal conditioners.
Relays (572811)
Used for sending of power to the heaters in a specific heat
zone.
Sensor (572815) Not Illustrated
Used for monitoring temperature within the confinement
space. Interfaces to the programmable controller to allow
operation of the Smart Sense™variable rate gas control
valves.
Signal Conditioners
Used to process the electrical signal from the programmable
controller for operation of the variable rate gas control
valves.
Forced Air Heaters : 572771
Radiant Brooders : 572913
Touch Pad / Display (572914)
Used for set up of the SmartBox
™
for system operation :
temperature , heating days, etc
Transformers
Used for reducing incoming 115 VAC to 24
VAC for powering of programmable controller and signal
conditioners.
Radiant Brooders (UPPER): 572912
Forced Air Heaters (LOWER): 570230
PROGRAMMABLE
CONTROLLER
FUSES
RELAYS
TRANSFORMERS
TOUCH PAD
AND DISPLAY
FIG. 1
FIG. 2
RADIANT FORCED AIR
SIGNAL CONDITIONERS