4.3.9

Relay Outputs

The VideoJet X40 has four relay outputs for switching external units such as lamps or alarm

sirens. You can operate these relay outputs manually while there is an active connection to the

VideoJet X40. The outputs can also be configured to automatically activate sirens or other

alarm units in response to an alarm signal. The relay outputs are also located on the orange

terminal block (see Section 8.7 Terminal Block, page 116).

X

Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4)

and check that the connection is secure.

4.3.10

Remote Indication of the Connection Status

When the VideoJet X40 is connected to a video, the Connect LED on the front panel of the

unit flashes. The LED also provides information on the operational state of the unit and signals

a unit defect (see Section 8.4 LEDs, page 114).

You can connect an additional two-color LED to the VideoJet X40 as a remote indicator. This

provides the same information as the integrated Connect LED. A remote indicator can be

useful if the VideoJet X40 is installed at a location that is difficult to access or see, for

example in a cable duct or on top of a mast. Just like the integrated LED, the remote indicator

LED should also light up red and green in order to avoid confusion.

Please comply with the following specifications and the connection diagram:

1.

Connect the LED lines to the appropriate terminals on the orange terminal block (RM1

and RM2) and check that the connection is secure.

2.

Check that the signals on the Connect LED on the VideoJet X40 and the remote indicator

LED correspond.

!

CAUTION!

A maximum load of 30 V and 2 A may be applied to the relay contacts.

Voltage between RM1 and RM2

3.3 V DC max.

Current between RM1 and RM2

25 mA max.

Source resistance

140 Ohm typ.