Detailed cooling capacities* continued – Bryant ELECTRIC AIR CONDITIONER 561C User Manual

Page 24

background image

—24—

DETAILED COOLING CAPACITIES* Continued

* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or

indoor unit is located above outdoor unit, a slight variation in capacity may occur.

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh

(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.

** Unit kw is total of indoor and outdoor unit kilowatts.
EWB—Entering Wet Bulb

EVAPORATOR

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

75

85

95

105

115

125

CFM

EWB

Capacity

MBtuh†

Total

Sys

KW**

Capacity

MBtuh†

Total

Sys

KW**

Capacity

MBtuh†

Total

Sys

KW**

Capacity

MBtuh†

Total

Sys

KW**

Capacity

MBtuh†

Total

Sys

KW**

Capacity

MBtuh†

Total

Sys

KW**

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

561C060-A, B, E Outdoor Section With CC5A/CD5AW060 Indoor Section

1750

72

66.3

32.0

5.14

63.7

31.0

5.64

61.0

30.0

6.20

58.1

28.9

6.82

55.0

27.8

7.50

51.7

26.6

8.24

67

60.6

40.0

4.96

58.1

38.9

5.46

55.6

37.9

6.01

52.9

36.7

6.63

50.0

35.6

7.30

47.1

34.4

8.02

62

55.2

47.8

4.81

52.9

46.7

5.30

50.6

45.5

5.85

48.1

44.3

6.46

45.4

42.9

7.12

42.8

41.5

7.80

57

51.8

51.8

4.72

50.0

50.0

5.22

48.2

48.2

5.78

46.3

46.3

6.40

44.2

44.2

7.07

42.1

42.1

7.77

1800

72

66.6

32.3

5.17

64.0

31.3

5.67

61.2

30.3

6.23

58.3

29.2

6.85

55.2

28.1

7.53

51.9

26.9

8.27

67

60.8

40.4

4.99

58.4

39.4

5.48

55.8

38.3

6.04

53.1

37.2

6.65

50.2

36.0

7.33

47.2

34.8

8.05

62

55.5

48.4

4.83

53.2

47.3

5.33

50.8

46.1

5.88

48.2

44.8

6.49

45.6

43.5

7.14

42.9

42.0

7.83

57

52.2

52.2

4.75

50.4

50.4

5.25

48.6

48.6

5.81

46.6

46.6

6.43

44.5

44.5

7.11

42.4

42.4

7.81

2100

72

68.1

33.9

5.34

65.3

32.9

5.83

62.4

31.8

6.39

59.4

30.7

7.01

56.1

29.6

7.69

52.8

28.4

8.43

67

62.2

43.1

5.14

59.7

42.1

5.64

57.0

41.0

6.20

54.2

39.8

6.81

51.2

38.6

7.48

48.0

37.4

8.21

62

56.7

52.0

4.98

54.4

50.8

5.48

51.9

49.5

6.03

49.3

48.0

6.64

46.6

46.3

7.30

44.1

44.1

8.01

57

54.6

54.6

4.93

52.7

52.7

5.43

50.7

50.7

5.99

48.6

48.6

6.62

46.4

46.4

7.29

44.1

44.1

8.01

2250

72

68.7

34.6

5.41

65.9

33.6

5.91

62.9

32.6

6.47

59.8

31.4

7.09

56.5

30.3

7.77

53.1

29.1

8.51

67

62.8

44.4

5.22

60.2

43.4

5.71

57.5

42.3

6.27

54.6

41.1

6.89

51.5

39.9

7.56

48.3

38.6

8.28

62

57.3

53.7

5.05

54.9

52.4

5.55

52.4

51.0

6.10

49.8

49.3

6.71

47.2

47.2

7.38

44.8

44.8

8.11

57

55.6

55.6

5.01

53.7

53.7

5.51

51.6

51.6

6.08

49.5

49.5

6.70

47.2

47.2

7.38

44.8

44.8

8.11

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Unit
Size

Cooling

Indoor

Section

Unit
Size

Cooling

Capacity

Power

Capacity

Power

CC5A/CD5AW

060

1.00

1.00

FG3AAA

060

0.99

1.00

CC5A/CD5AA

060

0.96

0.97

FK4CNB

006

1.02

1.00

CE3AA

060

1.01

0.99

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

CK3BA

060

0.96

1.00

CK3BA

060

0.96

0.95

CK5A/CK5BA

060

0.96

0.97

CK5A/CK5BA

060

0.96

0.95

CK5A/CK5BN

060

0.96

0.98

CK5A/CK5BX

060

1.00

0.95

CK5A/CK5BX

060

1.00

1.00

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

F(A,B)4AN(F,B)

060

1.01

1.05

CK3BA

060

0.96

0.96

FB4ANB

070

1.02

1.03

CK5A/CK5BA

060

0.96

0.96

FC4BN(F,B)

060

1.00

1.04

CK5A/CK5BX

060

0.96

0.96

FC4BNB

070

1.02

1.02