PERFORMANCE DATA (cont)
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE
-10–20
HEATING EXTENDED PERFORMANCE TABLE 30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.
601A060 (5 TONS)
Temp (F)
Air Ent
Outdoor Coil
(Edb)
Indoor Entering Air—CFM/BF
1750/0.079
2000/0.099
2250/0.167
Indoor Entering Air—Ewb (F)
72
67
63*
62
72
67
63*
62
72
67
63*
62
85
TC
64.8
59.9
55.9
54.9
64.8
59.9
55.9
53.7
64.8
59.9
55.9
55.0
SHC
34.6
45.4
44.2
53.7
34.6
45.4
44.2
52.0
34.6
45.4
44.2
55.0
kW
5.73
5.64
5.59
5.59
5.73
5.64
5.59
5.61
5.73
5.64
5.59
5.58
95
TC
62.6
57.5
53.2
52.6
62.6
57.5
52.9
52.7
62.6
57.5
53.4
52.8
SHC
33.9
44.7
42.9
51.3
33.9
44.7
42.4
52.0
33.9
44.7
43.5
52.8
kW
6.21
6.11
6.09
6.10
6.21
6.11
6.08
6.05
6.21
6.11
6.08
6.01
105
TC
60.0
54.8
50.6
50.4
60.0
54.7
49.8
50.6
60.0
54.8
50.7
50.0
SHC
33.2
43.8
42.3
50.4
33.2
43.7
41.3
50.6
33.2
43.8
42.0
50.0
kW
6.72
6.61
6.56
6.52
6.72
6.61
6.61
6.52
6.72
6.61
6.58
6.50
115
TC
57.0
51.9
47.3
48.2
57.0
51.9
47.4
47.9
57.0
51.9
47.5
15.8
SHC
32.2
42.7
41.3
46.7
32.2
42.7
40.2
47.9
32.2
42.7
40.3
7.8
kW
7.25
7.15
7.03
7.04
7.25
7.15
7.08
7.09
7.25
7.15
7.07
5.46
601A060 (5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
-10
0
10
17
20
60
1750
TC
17.98
16.57
23.50
21.59
28.92
26.51
33.54
30.53
35.75
32.24
kW
3.90
4.01
4.13
4.22
4.27
2000
TC
18.38
16.87
23.90
21.89
29.32
26.91
34.04
31.03
36.25
32.64
kW
3.97
4.07
4.18
4.26
4.30
2250
TC
18.78
17.27
24.30
22.29
29.73
27.32
34.34
31.33
36.65
33.04
kW
4.04
4.14
4.23
4.31
4.35
70
1750
TC
16.77
15.36
22.29
20.49
27.92
25.61
32.44
29.63
34.75
31.33
kW
4.14
4.29
4.43
4.53
4.59
2000
TC
17.17
15.77
22.80
20.89
28.32
26.01
32.94
30.03
35.25
31.83
kW
4.22
4.34
4.47
4.57
4.62
2250
TC
17.57
16.17
23.20
21.29
28.82
26.41
33.44
30.53
35.75
32.24
kW
4.29
4.41
4.53
4.62
4.66
80
1750
TC
15.26
14.06
20.99
19.28
26.71
24.60
31.33
28.52
33.54
30.23
kW
4.40
4.57
4.75
4.87
4.93
2000
TC
15.67
14.36
21.49
19.68
27.32
25.01
31.83
29.02
34.14
30.73
kW
4.47
4.63
4.79
4.90
4.95
2250
TC
16.07
14.76
21.89
20.08
27.72
25.41
32.34
29.52
34.65
31.23
kW
4.55
4.70
4.84
4.94
4.99
601A060 (5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
30
40
47
50
60
60
1750
TC
43.18
37.86
51.52
51.52
57.74
57.74
58.55
58.55
64.97
64.97
kW
4.42
4.59
4.67
4.68
4.76
2000
TC
43.68
38.26
51.92
51.92
58.15
58.15
59.55
59.55
65.98
65.98
kW
4.44
4.59
4.66
4.71
4.79
2250
TC
44.19
38.66
51.92
51.92
58.35
58.35
59.95
59.95
67.08
67.08
kW
4.48
4.60
4.71
4.75
4.86
70
1750
TC
42.28
37.06
50.61
50.61
57.24
57.24
59.15
59.15
64.57
64.57
kW
4.76
4.95
5.10
5.13
5.30
2000
TC
42.88
37.56
51.22
51.22
57.34
57.34
59.55
59.55
65.68
65.68
kW
4.77
4.94
5.06
5.10
5.16
2250
TC
43.38
37.96
51.62
51.62
57.94
57.94
59.55
59.55
66.98
66.98
kW
4.80
4.96
5.07
5.09
5.16
80
1750
TC
41.07
36.05
49.51
49.51
56.44
56.44
58.55
58.55
64.07
64.07
kW
5.13
5.34
5.52
5.57
5.72
2000
TC
41.68
36.55
50.21
50.21
56.94
56.94
58.75
58.75
65.58
65.58
kW
5.13
5.32
5.48
5.51
5.64
2250
TC
42.28
37.06
50.81
50.81
57.14
57.14
59.35
59.35
66.88
66.88
kW
5.16
5.34
5.46
5.50
5.63