PERFORMANCE DATA (cont)
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE
-10–20
HEATING EXTENDED PERFORMANCE TABLE 30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.
601A042 (3.5 TONS)
Temp (F)
Air Ent
Outdoor Coil
(Edb)
Indoor Entering Air—CFM/BF
1225/0.06
1400/0.075
1575/0.110
Indoor Entering Air—Ewb (F)
72
67
63*
62
72
67
63*
62
72
67
63*
62
85
TC
46.5
43.0
39.9
39.2
47.1
43.8
40.7
40.4
47.4
44.4
41.4
41.4
SHC
24.1
30.7
29.4
36.5
25.3
32.8
31.6
39.0
26.4
34.9
33.6
41.4
kW
4.11
4.04
3.98
3.96
4.12
4.05
3.99
3.99
4.13
4.06
4.00
4.01
95
TC
45.0
41.3
37.9
37.3
45.7
42.0
38.8
38.5
46.1
42.6
39.6
39.8
SHC
23.6
30.0
28.5
35.5
24.8
32.1
30.6
37.9
26.1
34.2
32.6
39.8
kW
4.48
4.39
4.29
4.27
4.49
4.41
4.32
4.32
4.49
4.42
4.36
4.37
105
TC
43.1
39.1
35.7
34.9
43.7
39.9
36.2
35.7
44.2
40.6
38.2
38.0
SHC
22.8
28.9
27.9
34.9
24.2
31.2
30.4
35.7
25.4
33.3
32.2
38.0
kW
4.84
4.75
4.59
4.59
4.86
4.78
4.63
4.59
4.87
4.80
4.84
4.71
115
TC
41.1
34.7
33.3
33.3
41.8
37.6
34.7
34.8
42.2
38.3
36.1
36.2
SHC
22.1
24.3
27.4
33.3
23.5
30.4
29.4
34.8
24.9
32.3
31.5
36.2
kW
5.23
4.88
4.90
4.92
5.25
5.11
5.01
4.98
5.27
5.15
5.13
5.05
601A042 (3.5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
-10
0
10
17
20
60
1225
TC
14.49
13.27
18.16
16.65
21.92
20.04
24.94
22.77
26.44
23.90
kW
2.63
2.73
2.83
2.91
2.95
1400
TC
14.77
13.55
18.54
17.03
22.30
20.42
25.31
23.05
26.82
24.18
kW
2.68
2.78
2.88
2.94
2.97
1575
TC
15.06
13.83
18.82
17.31
22.58
20.70
25.59
23.34
27.10
24.46
kW
2.75
2.83
2.92
2.98
3.01
70
1225
TC
13.46
12.33
17.31
15.90
21.17
19.48
24.18
22.02
25.69
23.15
kW
2.74
2.88
3.01
3.10
3.14
1400
TC
13.74
12.70
17.69
16.18
21.55
19.76
24.56
22.39
26.06
23.52
kW
2.80
2.93
3.06
3.13
3.17
1575
TC
14.11
12.99
17.97
16.56
21.92
20.14
24.94
22.68
26.44
23.81
kW
2.87
2.98
3.11
3.17
3.20
80
1225
TC
12.23
11.29
16.28
14.96
20.32
18.63
23.34
21.27
24.84
22.39
kW
2.83
3.00
3.18
3.28
3.33
1400
TC
12.51
11.57
16.65
15.24
20.70
19.01
23.71
21.64
25.22
22.77
kW
2.90
3.06
3.22
3.32
3.36
1575
TC
12.89
11.86
16.94
15.62
21.08
19.29
24.09
21.92
25.59
23.05
kW
2.96
3.11
3.27
3.36
3.40
601A042 (3.5 TONS)
Temp (F)
Indoor Air Cfm (std)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
Ent Indoor Coil
30
40
47
50
60
60
1225
TC
31.43
27.57
36.89
36.89
40.84
40.84
41.40
41.68
42.91
42.91
kW
3.06
3.18
3.27
3.27
3.20
1400
TC
31.80
27.85
36.98
36.98
41.03
41.03
41.50
40.46
43.94
43.94
kW
3.07
3.19
3.28
3.29
3.23
1575
TC
32.09
28.13
37.07
36.41
41.50
38.67
41.59
39.71
46.01
46.01
kW
3.11
3.20
3.27
3.39
3.34
70
1225
TC
30.77
27.01
36.04
36.04
40.65
40.65
41.21
41.21
44.41
44.41
kW
3.28
3.40
3.55
3.58
3.52
1400
TC
31.15
27.29
36.51
36.51
40.74
40.74
41.31
41.31
45.07
45.07
kW
3.29
3.42
3.54
3.51
3.54
1575
TC
31.43
27.57
36.70
36.70
40.84
40.84
41.40
41.40
46.48
46.48
kW
3.31
3.44
3.54
3.48
3.64
80
1225
TC
29.83
26.16
35.19
35.19
39.71
39.71
41.12
41.12
45.54
45.54
kW
3.49
3.65
3.77
3.81
3.85
1400
TC
30.30
26.53
35.76
35.76
40.18
40.18
41.21
41.21
46.39
46.39
kW
3.51
3.64
3.78
3.81
3.90
1575
TC
30.67
26.91
36.04
36.04
40.27
40.27
41.31
41.31
47.42
47.42
kW
3.54
3.66
3.78
3.82
4.00