Appendix i. model number significance, Model number nomenclature, Serial number format – Bryant 548J User Manual
Page 68
68
APPENDIX I. MODEL NUMBER SIGNIFICANCE
MODEL NUMBER NOMENCLATURE
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18
5 4 8 J P 0 6 A 0 0 0 A 0 B 0 A A --
____________
______
________
______
Unit Type
Design Revision
548J = High Eff. Heat Pump
--- = First Revision
Voltage
Packaging
E = 460---3---60
A = Standard
J = 208/230---1---60
B = LTL
P = 208/230---3---60
T = 575---3---60
Factory Installed Options
Cooling Tons
04 = 3 Ton
07 = 6 Ton
Outdoor Air Options
05 = 4 Ton
08 = 7.5 Ton
A = None
06 = 5 Ton
09 = 8.5 Ton
B = Temp econo w/ baro relief
E = Temp econo w/ baro relief & CO
2
Refrig. System Options
H = Enthalpy econo w/ baro relief
A = One---Stage Cooling Models
L = Enthalpy econo w/ baro relief & CO
2
D = Two---Stage Cooling Models
Q = Motorized 2 pos damper
Heat Level (Field---installed electric heaters available)
Indoor Fan Options
000 = No Heat
0 = Electric Drive X13 Motor (04---06)
1 = Standard static option --- Belt Drive
Coil Options (Outdoor --- Indoor)
2 = Medium static option --- Belt Drive
A = Al/Cu ---Al/Cu
3 = High static option --- Belt Drive
B = Precoat Al/Cu --- Al/Cu
C = E---coat Al/Cu --- Al/Cu
D = E---coat Al/Cu --- E---coat Al/Cu
E = Cu/Cu --- Al/Cu
F = Cu/Cu --- Cu/Cu
M = Al/Cu --- Al/Cu --- Louvered Hail guards
N = Precoat Al/Cu --- Al/Cu --- Louvered Hail Guards
P = E coat Al/Cu --- Al/Cu --- Louvered Hail Guards
Q = E coat Al/Cu --- E coat Al/Cu --- Louvered Hail Guards
R = Cu/Cu --- Al/Cu --- Louvered Hail Guards
S = Cu/Cu --- Cu/Cu --- Louvered Hail Guards
Serial Number Format
POSITION NUMBER
1
2
3
4
5
6
7
8
9
10
TYPICAL
0
4
0
9
G
1
2
3
4
5
POSITION
DESIGNATES
1---2
Week of manufacture (fiscal calendar)
3---4
Year of manufacture (“08” = 2008)
5
Manufacturing location (G = ETP, Texas, USA)
6---10
Sequential number
548J