beautypg.com

3 audio connections – Behringer DSP1200P User Manual

Page 34

background image

34

with the identical type and rating. NEVER use fuses of different ratings or cover faulty fuses with aluminium foil.

This can cause fire and electric shocks and will endanger your life and the lives of others.

5.3 Audio connections

As standard, the BEHRINGER MODULIZER PRO is installed with electronically servo-balanced inputs and

outputs. The new circuit design features automatic hum and noise reduction for balanced signals and thus

allows for trouble-free operation, even at high operating levels. Externally induced mains hum etc. will be

effectively suppressed. The automatic servo-function recognizes the presence of unbalanced connectors and

adjusts the nominal level internally to avoid level differences between the input and output signals (correction

6 dB).

+

Please ensure that only qualified persons install and operate the MODULIZER PRO. During

installation and operation the user must have sufficient electrical contact to earth. Electro-

static charges might affect the operation of the MODULIZER PRO!

1

2

3

2

1

3

Pin 1

Cable

Input

Output

Pin 2 = (+) Signal

Positive

Pin 3 = (-) Signal

Shield

(+) Signal + Hum

(-) Signal + Hum

Negative

(+)Hum + Signal

(-)Hum + Signal

2 x Signal

Ground

RFI and Hum

= Signal + 6 dB

Fig. 5.1: Compensation of interference with balanced connections

5. INSTALLATION