Bryant COMMERCIAL AIR COOLED CONDENSING UNITS 576b User Manual
Page 4
—
4
—
DIMENSIONS (ft-in.)
UNIT
A
B
C
D
E
F
With Aluminum Coils (Standard)
569C072
1-6
1
/
2
1-2
3
/
4
—
1-2
1
/
4
1-4
5
/
16
2-9
5
/
16
569C090
1-8
1-6
1
/
2
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
569C120
1-9
1-8
2-0
1-3
2-
5
/
16
3-5
7
/
16
576B090
1-6
1-4
3
/
4
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
576B102
1-7
1-5
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
576B120
1-7
1-5
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
With Copper Coils (Optional)
569C072
1-8
1-3
—
1-2
1
/
4
1-4
5
/
16
2-9
5
/
16
569C090
1-9
1
/
2
1-6
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
569C120
1-10
1-7
2-0
1-3
2-
5
/
16
3-5
7
/
16
576B090
1-7
1
/
2
1-4
1
/
2
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
576B102
1-7
1
/
2
1-4
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
576B120
1-7
1
/
2
1-4
2-9
13
/
16
1-3
2-
5
/
16
3-5
7
/
16
ELECTRICAL CONNECTIONS
SERVICE VALVE CONNECTIONS
WEIGHT CHART (lb)
NOTE: Al indicates weight with aluminum-fin coil (standard);
Cu indicates weight with copper-fin coil (optional).
CONNECTION SIZES
AA
1
3
/
8
″ Dia Field Power Supply Hole
BB
2
″ Dia Power Supply Knockout
CC
2
1
/
2
″ Dia Power Supply Knockout
DD
7
/
8
″ Dia Field Control Wiring Hole
UNIT
SUCTION
LIQUID
569C072
1
1
/
8
″
1
/
2
″
569C090
1
1
/
8
″
1
/
2
″
569C120
1
1
/
8
″
5
/
8
″
576B090
1
1
/
8
″
1
/
2
″
576B102
1
1
/
8
″
5
/
8
″
576B120
1
1
/
8
″
5
/
8
″
UNIT
STD UNIT
CORNER W
CORNER X
Al
Cu
Al
Cu
Al
Cu
569C072
340
386
86
106
53
65
569C090
392
460
91
120
84
100
569C120
426
503
96
126
99
126
576B090
510
578
114
143
89
106
576B102
564
632
133
161
97
114
576B120
564
632
133
161
97
114
UNIT
CORNER Y
CORNER Z
Al
Cu
Al
Cu
569C072
77
82
124
133
569C090
105
113
113
127
569C120
117
127
113
127
576B090
133
142
173
187
576B102
141
150
193
207
576B120
141
150
193
207
NOTES:
1. Dimensions in [
] are in millimeters.
2.
Center of Gravity. See chart for dimensions.
3.
Direction of airflow.
4. Minimum clearance (local codes or jurisdiction may prevail):
a. Bottom to combustible surfaces, 0 inches.
b. Either left or rear side of condensing unit must have 36-in. clearance for proper airflow;
the remaining side(s) must have 12-in. clearance each.
c. Overhead, 60 in., to assure proper condenser fan operation.
d. Between units, control box side, 42 in. per NEC (National Electrical Code).
e. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.
f. Between unit and block or concrete walls and other grounded surfaces, control box side,
42 in. per NEC.
5. With the exception of the clearance for the condenser coil as stated in Note 4b, a removable
fence or barricade requires no clearance.
6. Units may be installed on combustible floors made from wood or Class A, B, or C roof cover-
ing material.
7. Certified dimension drawings available on request.
Fig. 2 — Base Unit Dimensions