Bryant COMMERCIAL AIR COOLED CONDENSING UNITS 576b User Manual

Page 4

background image

4

DIMENSIONS (ft-in.)

UNIT

A

B

C

D

E

F

With Aluminum Coils (Standard)

569C072

1-6

1

/

2

1-2

3

/

4

1-2

1

/

4

1-4

5

/

16

2-9

5

/

16

569C090

1-8

1-6

1

/

2

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

569C120

1-9

1-8

2-0

1-3

2-

5

/

16

3-5

7

/

16

576B090

1-6

1-4

3

/

4

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

576B102

1-7

1-5

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

576B120

1-7

1-5

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

With Copper Coils (Optional)

569C072

1-8

1-3

1-2

1

/

4

1-4

5

/

16

2-9

5

/

16

569C090

1-9

1

/

2

1-6

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

569C120

1-10

1-7

2-0

1-3

2-

5

/

16

3-5

7

/

16

576B090

1-7

1

/

2

1-4

1

/

2

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

576B102

1-7

1

/

2

1-4

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

576B120

1-7

1

/

2

1-4

2-9

13

/

16

1-3

2-

5

/

16

3-5

7

/

16

ELECTRICAL CONNECTIONS

SERVICE VALVE CONNECTIONS

WEIGHT CHART (lb)

NOTE: Al indicates weight with aluminum-fin coil (standard);
Cu indicates weight with copper-fin coil (optional).

CONNECTION SIZES

AA

1

3

/

8

″ Dia Field Power Supply Hole

BB

2

″ Dia Power Supply Knockout

CC

2

1

/

2

″ Dia Power Supply Knockout

DD

7

/

8

″ Dia Field Control Wiring Hole

UNIT

SUCTION

LIQUID

569C072

1

1

/

8

1

/

2

569C090

1

1

/

8

1

/

2

569C120

1

1

/

8

5

/

8

576B090

1

1

/

8

1

/

2

576B102

1

1

/

8

5

/

8

576B120

1

1

/

8

5

/

8

UNIT

STD UNIT

CORNER W

CORNER X

Al

Cu

Al

Cu

Al

Cu

569C072

340

386

86

106

53

65

569C090

392

460

91

120

84

100

569C120

426

503

96

126

99

126

576B090

510

578

114

143

89

106

576B102

564

632

133

161

97

114

576B120

564

632

133

161

97

114

UNIT

CORNER Y

CORNER Z

Al

Cu

Al

Cu

569C072

77

82

124

133

569C090

105

113

113

127

569C120

117

127

113

127

576B090

133

142

173

187

576B102

141

150

193

207

576B120

141

150

193

207

NOTES:
1. Dimensions in [

] are in millimeters.

2.

Center of Gravity. See chart for dimensions.

3.

Direction of airflow.

4. Minimum clearance (local codes or jurisdiction may prevail):

a. Bottom to combustible surfaces, 0 inches.

b. Either left or rear side of condensing unit must have 36-in. clearance for proper airflow;

the remaining side(s) must have 12-in. clearance each.

c. Overhead, 60 in., to assure proper condenser fan operation.

d. Between units, control box side, 42 in. per NEC (National Electrical Code).
e. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.

f. Between unit and block or concrete walls and other grounded surfaces, control box side,

42 in. per NEC.

5. With the exception of the clearance for the condenser coil as stated in Note 4b, a removable

fence or barricade requires no clearance.

6. Units may be installed on combustible floors made from wood or Class A, B, or C roof cover-

ing material.

7. Certified dimension drawings available on request.

Fig. 2 — Base Unit Dimensions