Downflow subbase dimensions -- in. (mm), 353aa v – Bryant PLUS 90X 353AAV User Manual

Page 8

background image

8

DOWNFLOW SUBBASE DIMENSIONS -- IN. (MM)

FURNACE

CASING

WIDTH

FURNACE IN DOWNFLOW APPLICATION

PLENUM OPENING

FLOOR OPENING

HOLE NO.

FOR

WIDTH

ADJUST---

MENT

A

B

C

D

17-1/2

(445)

Furnace with or without Cased Coil Assembly or

Coil Box

15---1/8

(384)

19

(483)

16-3/4

(425)

20---3/8

(518)

3

21

(533)

Furnace with or without Cased Coil Assembly or

Coil Box

18---5/8

(473)

19

(483)

20---1/4

(514)

20---3/8

(518)

2

24-1/2

(622)

Furnace with or without Cased Coil Assembly or

Coil Box

22-1/8

(562)

19 (483)

23-3/4

(603)

20---3/8

(518)

1

*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.

C

A

1 1/4″ (32 μμ) TYP

PLENUM
OPENING

FACTORY-SUPPLIED

FIELD-INSTALLED

INSULATION

LOCATING

TAB

4

3

2

1

1

2

3

4

B

D

LOCATING

TAB

COMBUSTION--AIR PIPE FOR NON--DIRECT VENT (1--PIPE) APPLICATION

(SIZES 040 THROUGH 120 ONLY)

LENGTH OF STRAIGHT

PIPE PORTION OF COMBUSTION

AIR INLET PIPE ASSEMBLY - IN. (mm)

CASING WIDTH

A

17-1/2

8-1/2 ± 1/2 (216 ± 13 mm)

21 (533 mm)

10-1/2 ± 1/2 (267 ± 13 mm)

24-1/2 (622 mm)

12 ± 1/2 (305 ± 13 mm)

A96211

FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE

FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC 90° ELBOW

COMBUSTION-AIR DISC
(FACTORY-SUPPLIED IN
LOOSE PARTS BAG)

A

(445 mm)

CONCENTRIC VENT FOR DIRECT VENT (2--PIPE) APPLICATION (ALL MODEL SIZES)

C IN. (MM) DIA

B IN. (MM) DIA PVC

VENT/EXHAUST

1

3

/

16 (30 mm)

B IN. (MM) DIA PVC

INTAKE/COMBUSTION AIR

D

E

F

A

1

1/2

(38 mm)

KIT PART NO.

A*

B

C

D{

E

F

KGAVT0701CVT

33---3/8 (848)

2 (51)

3---1/2 (89)

16---5/8 (422)

6---1/4 (159)

5---3/4 (146)

KGAVT0801CVT

38---7/8 (987)

3 (76)

4---1/2 (114)

21---1/8 (537)

7---3/8 (187)

6---1/2 (165)

*Dimension A will change accordingly as Dimension D is lengthened or shortened.

{

Dimension D may be lengthened to 60---in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12--- in. (305

mm) minimum.

353AA

V