beautypg.com

Bryant PLUS 90X 353AAV User Manual

Page 3

background image

3

12

11

6

8

10

9

7

6

4

5

2

1

13

14

18

3

15

16

17

19
20

A08421

1.

Burner sight glass for viewing burner flame.

2.

Burner assembly (inside), operates with energy--sav-

ing, inshot burners and hot surface igniter for safe,

dependable heating.

3.

Combustion--air intake connection to ensure contam-

inant--free air (right or left side).

4.

Redundant gas valve, safe, efficient, features 1 gas

control with 2 internal shutoff valves.

5.

Junction box for 115--v electrical power supply.

(right or left side)

6.

Vent outlet uses sealed PVC pipe to carry vent gases

from the furnace’s combustion system (right or left

side).

7.

Secondary condensing heat exchanger (inside),

wrings out more heat through condensation of gases.

Constructed with polypropylene--laminated steel to

ensure durability.

8.

Pressure switch ensures adequate flow of flue

products through furnace and out vent system.

9.

Inducer motor pulls hot flue gases through the heat

exchangers, maintaining negative pressure for added

safety.

10.

Condensate drain connection collects moisture con-

densed during the combustion process.

1 2 3 4 5 6

11.

Heavy--duty blower circulates air across the heat

exchangers to transfer heat into the home.

12.

Air filter and retainer may be used for side or bottom

return application.

13.

Rollout switch (manual reset) to prevent overtemper-

ature in burner area.

14.

Primary serpentine heat exchanger (inside). Stretches

fuel dollars with the S--shaped heat--flow design. Sol-

id weld--free construction of corrosion--resistant alu-

minized steel means reliability.

15.

A 3--amp fuse provides electrical and component

protection.

16.

Light emitting diode (LED) on control center. Code

lights are for diagnosing furnace operation and ser-

vice requirements.

17.

Control center.

18.

Blower access panel safety interlock switch.

19.

Transformer (24v) behind control center provides

low--voltage power to furnace control center and

thermostat.

20. Power choke (used with 1 HP and 3/4 HP motors.)

353AA

V