TROUBLESHOOTING GUIDE (Cont.)

Error Codes (Continued)

LED DISPLAY

ERROR

DESCRIPTION/TROUBLESHOOTING

Tank Temp Sensor Failed

Sensor Reading Out Of Range (High

or Low). Faulty Sensor wiring.

Switch Board Failure

Unable To Communicate With The

Switch Board In The Door. Faulty

wiring between the Door and the Main

Control Board.

39288 072707

Power Supply Failure

Power Supply voltage is outside the

allowable limits (23 - 26 Vdc). Faulty

wiring. Blown fuse inside Power

Supply, failed supply.

Heat Sink Temp Too High

Cool Temp Sensor Failed

Sensor Reading Out Of Range (High

or Low). Faulty Sensor wiring.

Heat Sink Temp Sensor Failed

Sensor Reading Out Of Range (High

or Low). Faulty Sensor wiring.

MENU

(-)

(+)

6

C

E

0 0

MENU

(-)

(+)

7

C

E

0 0

MENU

(-)

(+)

8

C

E

0 0

MENU

(-)

(+)

9

C

E

0 0

MENU

(-)

(+)

0

C

E

0 1

MENU

(-)

(+)

1

C

E

0 1

WARNING: Empty BIB LED’s flash

slowly. Heat Sink Temp above 150°F

(65°C). Check: Air Filter plugged or

blocked, Ambient Operating Temp Too

High >90°F (32°).

FAULT: All LED’s Flash& Chiller Turned

OFF.

Heat Sink Temp above 170°F (77°C).

Check: Air Filter plugged or blocked,

Ambient Operating Temp Too High

>90°F (32°).