CALIBRATING THE DISPENSER (Cont.)

LCD DISPLAY

CALIBRATION MODE

DESCRIPTION

Right (Decaf) Water Rate

Enter Liters collected from the 20 sec.

test above.

Default = 1.08

Range = 0.95 - 1.12 Liters

Cooler Control Temperature

Delays the Pump turn off after a

dispense.

Default = 200

Range = 1 - 999 mSec.

Reset Factory Defaults

Resets all set up values to the Factory

Default setting.

Hold both Increase (+) and Decrease

(-) switch for 10 seconds.

Displays Software Version # -

Exits To Home View After 3 Seconds.

English or Metric Mode

Used to select the desired units.

Default = English

Eng for English

S.I. for Metric

Error Code Memory

Display cycles through the last (3)

Error Codes.

Erase by holding both the Decrease (-)

& Increase (+) switches for 10 sec.

39288 072707

Pump “OFF” Delay

Used to set the Target Temperature for

the Product Cabinet.

Default = 65°F (18°C)

Range = 50° - 75°F (10° - 24°C)

MENU

(-)

(+)

C 4 1.0 8

MENU

(-)

(+)

C 5 0 6 5

MENU

(-)

(+)

- - -

C 9

MENU

(-)

(+)

x x

C

L

MENU

(-)

(+)

C 6 2 0 0

MENU

(-)

(+)

C 8 E x x

MENU

(-)

(+)

C 7 En g

Maximum Cooling Mode

Set Product Cabinet Target Temperature

to 50°F (10°C). Then continue to hold

the decrease (-) switch for 10 sec. Unit

will display “CHL”. Chiller will now

attempt to cool the product cabinet to

45°F (7°C). To disable this mode, hold

the increase (+) switch for 10 sec. Then

adjust to the desired Cabinet Temp.

NOTE: All Cabinet Temperature

Warnings are disabled when in the

Max. Cooling Mode.

MENU

(-)

(+)

C 5 CH L