C 1 r u n, C 1 2 2, C 2 r u n – Bunn Chilled LCC-2 User Manual

Page 20: C 2 2 2, C 3 r u n, C 3 1.0 8, C 4 r u n

background image

20

Right (Decaf) Water Rate

Set PRIME-NORMAL-RINSE switch to

RINSE position. Press and hold Decaf

Dispense Switch until flow stops (20

sec.) Refer to Field Calibration of the

Concentrate Pumps.

LCD DISPLAY

CALIBRATION MODE

DESCRIPTION

CALIBRATING THE DISPENSER

Left (Regular) Pump Cal.

Set PRIME-NORMAL-RINSE switch

to PRIME position. Press and hold

Regular Dispense Switch until pump

stops (20 sec.) Refer to Field Calibration

of the Concentrate Pumps.

NOTE: The LCA-2 LP is calibrated at the factory and does not normally need to be re-calibrated. To enter the

Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold the “MENU”

switch down for 10 seconds.

Left (Regular) Pump Cal.

Enter mL collected from the 20 sec.

test above.

Default = 22

Range = 18 - 26mL

Right (Decaf) Pump Cal.

Set PRIME-NORMAL-RINSE switch to

PRIME position. Press and hold Decaf

Dispense Switch until pump stops (20

sec.) Refer to Field Calibration of the

Concentrate Pumps.

Right (Decaf) Pump Cal.

Enter mL collected from the 20 sec.

test above.

Default = 22

Range = 18 - 26mL

Left (Regular) Water Rate

Set PRIME-NORMAL-RINSE switch to

RINSE position. Press and hold Regular

Dispense Switch until flow stops (20

sec.) Refer to Field Calibration of the

Concentrate Pumps.

Left (Regular) Water Rate

Enter Liters collected from the 20 sec.

test above.

Default = 1.08

Range = 0.95 - 1.12 Liters

39288 072707

MENU

(-)

(+)

C 1 r u n

MENU

(-)

(+)

C 1

2 2

MENU

(-)

(+)

C 2 r u n

MENU

(-)

(+)

C 2

2 2

MENU

(-)

(+)

C 3 r u n

MENU

(-)

(+)

C 3 1.0 8

MENU

(-)

(+)

C 4 r u n